Certifications

  • Archiloom

    Download the fire safety test report by SGS. Certification standard: CAN/ULC-102:2019(R2024).

    Download
  • PanFlex

    Download the fire safety test report by SGS. Certification standard: CAN/ULC-102:2019(R2024).

    Download
  • BétonFlex

    Download the fire safety test report by SGS. Certification standard: CAN/ULC-S102:2019(R2024).

    Download

Acoustic performance

ARTMUR panels bring together design and acoustics, effectively reducing ambient noise. Their felt has an average NRC of 0.8, which means it can absorb up to 80% of sound.
The wood slats diffuse part of the sound waves while the polyester felt absorbs much of the rest, for an actual NRC of 0.55 to 0.66, which corresponds to absorption class D.
For maximum performance, adding mineral wool behind the panel brings it up to absorption class A.

Air quality certification (VOC)

Indoor air can be laden with volatile organic compounds (VOCs) from building materials and furniture.
ARTMUR panels meet the strictest standards and are rated A+, the highest level, for a healthy indoor environment with low emissions.

Fire protection

The National Building Code of Canada (NBCC) sets strict requirements for wall and ceiling finishes to limit flame spread.
Under article 2.2.1.12, the flame spread index must not exceed 150, with even stricter standards for high-rise buildings (section 3.1.13.7).

ARTMUR panels far exceed these requirements:

  • Flame spread index < 25
  • Smoke developed index < 50

They are therefore compliant and safe for all types of construction in Canada: residential, commercial or institutional.